Kitchen
NEC 210.12(A), 210.8(A)(6)GFCI: countertop receptacles & within 6 ft of sink
Ask Sparky about this roomBathrooms
NEC 210.12(A), 210.8(A)(1)GFCI: all receptacles
Ask Sparky about this roomLaundry Area
NEC 210.12(A), 210.8(A)(10)GFCI: within 6 ft of sink or all laundry receptacles
Ask Sparky about this roomGarage
NEC 210.12(A), 210.8(A)(2)GFCI: all receptacles
Ask Sparky about this roomUnfinished Basement
NEC 210.12(A), 210.8(A)(5)GFCI: all receptacles
Ask Sparky about this roomFinished Basement
NEC 210.12(A)GFCI only in wet areas (bar sink, bathroom)
Ask Sparky about this roomCrawl Space
NEC 210.8(A)(4)GFCI: all receptacles at or below grade
Ask Sparky about this roomPool / Hot Tub Area
NEC 680.22GFCI: all receptacles within 20 ft
Ask Sparky about this roomNEC Reference
AFCI requirements: NEC 210.12 — Arc-fault circuit-interrupter protection for dwelling units.
GFCI requirements: NEC 210.8(A) for dwelling units, 210.8(B) for other than dwelling units.
Always verify with your local AHJ (Authority Having Jurisdiction) — local amendments may modify these requirements.